Industrial Automation
Recommended ratings: IP54, IP55, IP65, IP66, IP67
Control panels, motors, and sensors in dusty, damp factories. IP54 for general use, IP65/IP66 for washdown and heavy dust.
Common use cases
- Factory control cabinets
- Conveyor sensors
- Machine tool electronics
- Plant-floor HMIs
IP ratings used in industrial automation
45 ratings mapped to this industry.
IP33 protects against tools and 2.5 mm objects plus spraying water up to 60° from vertical. A practical rating for indoor equipment subject to light spray or for sheltered outdoor fixtures.
IP54 is dust-protected (limited ingress, no harmful deposit) and resists splashing water from any direction. A versatile rating for industrial and outdoor-covered equipment in dusty, damp environments.
IP55 is dust-protected and resists low-pressure water jets (6.3 mm nozzle, 30 kPa). A popular industrial rating for equipment exposed to dust and directed water spray but not immersion.
IP56 is dust-protected and resists powerful water jets (12.5 mm nozzle, 100 kPa). Suited to outdoor equipment subjected to heavy rain or hose-directed water.
IP57 is dust-protected and tolerates temporary immersion up to 1 m for 30 minutes. Useful for portable devices that may be dropped in shallow water.
IP65 is dust-tight and resists low-pressure water jets (6.3 mm nozzle, 30 kPa). It is the most common standard for fully exposed outdoor electronics such as lighting, cameras, and EV chargers.
IP66 is dust-tight and resists powerful water jets (12.5 mm nozzle, 100 kPa). A robust outdoor rating for equipment exposed to heavy rain, storms, or directed high-pressure hosing (but not high-pressure washdown).
IP67 is dust-tight and withstands temporary immersion in water up to 1 meter for 30 minutes. The go-to rating for outdoor and rugged devices that may be briefly submerged.
IP68 is dust-tight and protects against continuous immersion in water under conditions specified by the manufacturer (typically deeper than 1 meter for prolonged periods). The standard for submersible and marine equipment.
IP69K is dust-tight and resists high-pressure (8–10 MPa), high-temperature (80 °C) water jets. The highest IP rating, required for food, beverage, and pharmaceutical washdown environments.
IPX6 resists powerful water jets (12.5 mm nozzle, 100 kPa) with solid protection not specified. Suitable for heavy-rain or hose-exposed equipment where dust sealing is not required.
IP5X is dust-protected (limited ingress, no harmful deposit) with water protection not specified. Used where dust limitation matters but the equipment is kept dry.
IP6X is fully dust-tight—no ingress of dust whatsoever—with water protection not specified. The highest solid-protection rating, used where complete dust exclusion is critical.
IP58 is dust-protected and rated for continuous immersion in water under manufacturer-specified conditions. A niche rating for equipment that must operate submerged while allowing limited dust ingress.
IP60 is dust-tight with no water protection. Used for indoor equipment in very dusty environments that stays completely dry — dust exclusion without any moisture tolerance.
IP64 is dust-tight and resists splashing water from any direction. A solid outdoor-covered rating combining complete dust exclusion with splash tolerance, sitting between IP65 (jets) and IP54 (dust-protected).
Under IEC 60529, IP05 specifies no protection against solid objects and protection against water jets. Water projected by a 6.3 mm nozzle against the enclosure from any direction shall have no harmful effects.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 0 with second-digit (liquid) level 5.
With IP06, an enclosure receives no protection against solid objects and protection against powerful water jets. Water projected in powerful jets by a 12.5 mm nozzle against the enclosure from any direction shall have no harmful effects.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 0 with second-digit (liquid) level 6.
IP07 is an ingress protection code that ensures no protection against solid objects and protection against the effects of temporary immersion in water. Ingress of water in quantities causing harmful effects shall not be possible.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 0 with second-digit (liquid) level 7.
Built to withstand no protection against solid objects and protection against the effects of continuous immersion in water under conditions specified by the manufacturer.. Classified as IEC 60529 ingress protection code IP08, it pairs solid level 0 with liquid level 8.
The IP09K rating offers no protection against solid objects and resistance to high-pressure (8–10 MPa), high-temperature (80 °C) water jets. It is an IEC 60529 ingress protection code combining first-digit (solid) level 0 with second-digit (liquid) level 9K.
With IP15, an enclosure receives protection against solid objects larger than 50 mm and protection against water jets. Water projected by a 6.3 mm nozzle against the enclosure from any direction shall have no harmful effects.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 1 with second-digit (liquid) level 5.
IP16 is an ingress protection code that ensures protection against solid objects larger than 50 mm and protection against powerful water jets. Water projected in powerful jets by a 12.5 mm nozzle against the enclosure from any direction shall have no harmful effects.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 1 with second-digit (liquid) level 6.
Built to withstand protection against solid objects larger than 50 mm and protection against the effects of temporary immersion in water. Ingress of water in quantities causing harmful effects shall not be possible.. Classified as IEC 60529 ingress protection code IP17, it pairs solid level 1 with liquid level 7.
The IP18 classification guarantees protection against solid objects larger than 50 mm and protection against the effects of continuous immersion in water under conditions specified by the manufacturer.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 1 with second-digit (liquid) level 8.
Under IEC 60529, IP19K specifies protection against solid objects larger than 50 mm and resistance to high-pressure (8–10 MPa), high-temperature (80 °C) water jets. It is an IEC 60529 ingress protection code combining first-digit (solid) level 1 with second-digit (liquid) level 9K.
IP25 is an ingress protection code that ensures protection against solid objects larger than 12.5 mm and protection against water jets. Water projected by a 6.3 mm nozzle against the enclosure from any direction shall have no harmful effects.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 2 with second-digit (liquid) level 5.
Built to withstand protection against solid objects larger than 12.5 mm and protection against powerful water jets. Water projected in powerful jets by a 12.5 mm nozzle against the enclosure from any direction shall have no harmful effects.. Classified as IEC 60529 ingress protection code IP26, it pairs solid level 2 with liquid level 6.
The IP27 classification guarantees protection against solid objects larger than 12.5 mm and protection against the effects of temporary immersion in water. Ingress of water in quantities causing harmful effects shall not be possible.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 2 with second-digit (liquid) level 7.
Specified under IEC 60529, IP28 denotes protection against solid objects larger than 12.5 mm and protection against the effects of continuous immersion in water under conditions specified by the manufacturer.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 2 with second-digit (liquid) level 8.
With IP29K, an enclosure receives protection against solid objects larger than 12.5 mm and resistance to high-pressure (8–10 MPa), high-temperature (80 °C) water jets. It is an IEC 60529 ingress protection code combining first-digit (solid) level 2 with second-digit (liquid) level 9K.
Built to withstand protection against solid objects larger than 2.5 mm and protection against water jets. Water projected by a 6.3 mm nozzle against the enclosure from any direction shall have no harmful effects.. Classified as IEC 60529 ingress protection code IP35, it pairs solid level 3 with liquid level 5.
The IP36 classification guarantees protection against solid objects larger than 2.5 mm and protection against powerful water jets. Water projected in powerful jets by a 12.5 mm nozzle against the enclosure from any direction shall have no harmful effects.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 3 with second-digit (liquid) level 6.
Specified under IEC 60529, IP37 denotes protection against solid objects larger than 2.5 mm and protection against the effects of temporary immersion in water. Ingress of water in quantities causing harmful effects shall not be possible.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 3 with second-digit (liquid) level 7.
IP38 provides protection against solid objects larger than 2.5 mm and protection against the effects of continuous immersion in water under conditions specified by the manufacturer.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 3 with second-digit (liquid) level 8.
IP39K is an ingress protection code that ensures protection against solid objects larger than 2.5 mm and resistance to high-pressure (8–10 MPa), high-temperature (80 °C) water jets. It is an IEC 60529 ingress protection code combining first-digit (solid) level 3 with second-digit (liquid) level 9K.
Specified under IEC 60529, IP46 denotes protection against solid objects larger than 1.0 mm and protection against powerful water jets. Water projected in powerful jets by a 12.5 mm nozzle against the enclosure from any direction shall have no harmful effects.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 4 with second-digit (liquid) level 6.
IP47 provides protection against solid objects larger than 1.0 mm and protection against the effects of temporary immersion in water. Ingress of water in quantities causing harmful effects shall not be possible.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 4 with second-digit (liquid) level 7.
Engineered to deliver protection against solid objects larger than 1.0 mm and protection against the effects of continuous immersion in water under conditions specified by the manufacturer.. Classified as IEC 60529 ingress protection code IP48, it pairs solid level 4 with liquid level 8.
Built to withstand protection against solid objects larger than 1.0 mm and resistance to high-pressure (8–10 MPa), high-temperature (80 °C) water jets. Classified as IEC 60529 ingress protection code IP49K, it pairs solid level 4 with liquid level 9K.
IP52 is an ingress protection code that ensures dust-protected (limited ingress, no harmful deposit) and protection against vertically falling drops of water when the enclosure is tilted up to 15° from its normal position.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 5 with second-digit (liquid) level 2.
Built to withstand dust-protected (limited ingress, no harmful deposit) and protection against spraying water. Water sprayed at an angle up to 60° on either side of the vertical shall have no harmful effects.. Classified as IEC 60529 ingress protection code IP53, it pairs solid level 5 with liquid level 3.
The IP59K classification guarantees dust-protected (limited ingress, no harmful deposit) and resistance to high-pressure (8–10 MPa), high-temperature (80 °C) water jets. It is an IEC 60529 ingress protection code combining first-digit (solid) level 5 with second-digit (liquid) level 9K.
Built to withstand dust-tight (no ingress of dust) and protection against vertically falling drops of water when the enclosure is tilted up to 15° from its normal position.. Classified as IEC 60529 ingress protection code IP62, it pairs solid level 6 with liquid level 2.
The IP63 classification guarantees dust-tight (no ingress of dust) and protection against spraying water. Water sprayed at an angle up to 60° on either side of the vertical shall have no harmful effects.. It is an IEC 60529 ingress protection code combining first-digit (solid) level 6 with second-digit (liquid) level 3.